| TLAX |
 |
| Visual level indicator with glass |
|
Transparent inspection window in Pyrex glass suitable for high and low temperatures from -20°C till + 200°C max.
Supplied complete with internal Viton washer.
By request supplied in brass.
|
|
|
  |
|
|
 |
| TLP |
| Visual level
indicator. |
Transparent inspection window unaffected by high or
low temperatures. Avoid contact with petrol,
benzine, alcohol, petroleum, solvents. O-ring
for pressure assembly.
Available with diameter measures from 17 to 38.
|
|
|
  |
|
|
 |
| TLA |
|
Visual level indicator.
|
Transparent inspection window
unaffected by high or low temperatures. Avoid contact with petrol,benzine,
alcohol, petroleum, solvents.
On request: with
transparent inspection window, proof against benzine
and petroleum;
with anchor nut for
unthreaded hole.
Available with gas trhead from 1/4" to 2" and metric trhead from
14,5x1,5 to 60x4.
|
|
|
 |
|
|
 |
| TLA/F |
| Visual level
indicator with milled
head. |
Transparent
inspection window is unaffected by high or low temperatures. Avoid contact with petrol,
benzine, alcohol, petroleum,
toluol. Head milling
produces a crown with greater sealing area against the
crankcase.
On request: with
transparent inspection, window proof against benzine
and petroleum.
Available with gas trhead from 3/8" to 1"-1/4 and metric trhead from 16x1,5
to 22x1,5.
|
|
|
 |
|
|
 |
| OBLÒ |
| Inspection porthole
or liquid-level ø100. |
|
Made of aluminium light alloy with tempered glass;
supplied complete with gum washers, anchor screws
and O-ring. For the tightening to build a central hole of 100 mm and 6 threaded
holes M6 arranged 60° on a diameter with
inter-axis of 130 mm. The thickness of the reservoir must not be less than
5 mm.
|
|
|
 |
|
|
 |
| OBLÒ |
| Inspection porthole
or liquid-level ø148. |
|
Made of aluminium light alloy with tempered glass;
supplied complete with gum washers, anchor screws
and O-ring. For the tightening to build a central hole of 148 mm and 8 threaded
holes M6 arranged 45° on a diameter with
inter-axis of 180 mm. The thickness of the reservoir must not be less than
5 mm.
|
|
|
 |
|
|
 |
| IFC |
| Dome-shaped level
gauge. |
Transparent glass that does not alter at high and
low temperatures. It is particularly suitable for seeing the
fluid from the side, as well as the circulation of fluid from the top. Avoid
contact with alcohol, solvents.
It is supplied with fixing nut for non-
threaded holes on request.
Available with gas trhead from 1/2" to 2"
and metric trhead from 20x1,5 to 52x1,5.
|
|
|
 |
|
|
 |
| GTSF |
| level indicator unit
with breather plug. |
This unit was designed to satisfy both technical and
economical requirements, because it can be applied
with a single hole obtaining three services: oil filling, vapor venting, level
indication. Avoid contact with petrol,
benzine, alcohol, petroleum, solvents.
On request: with transparent inspection
window proof against benzine and
petroleum.
Available with gas thread from 3/8" to 1" and metric thread from
16x1,5 to 33x2.
|
|
|
 |
|
 |
|
 |
|
 |
| GLVX |
 |
| Vertical level indicator with double thread, with pyrex glass and protection. |
Vertical level indicator with double thread to control fluid
level. Realized with aluminium light alloy little blocks,
transparent tube made in pyrex glass and Viton O-Rings.
Suitable for low and high temperatures -20°C + 200°C max.
Supplied complete with protection.
Available with gas thread 3/8” – M10 and M12
|
|
|
| GLVE |
 |
| Vertical level indicator with double electrical contact. |
Used for the control of the fluid for tanks. The electrical sensor indicates the attainment of the MIN and MAX level of the fluid.
The contacts are normally opened, they close to the attainment of the MIN or MAX level.
Available with length variable, on request of customer, from a minimum of 200 mm to a maximum of 2.000 mm.
Supplied complete of connectors.
Electrical characteristics: Maximum load on the electrical contacts:
- AC till 125 Volt – 1,0 A – 10 VA
- DC till 100 Volt – 1,0 A – 10 VA
For further information please demand the electrical plan. Avoid contacts with alcohol, trichloroethylene, solvents, petrol and petroleum.
Available with gas thread 3/8”
|
|
|
| LGF68 |
 |
| Flanged level indicator with float system. |
Composed of aluminium light alloy flanged cover with orientable dial.
Complete with float system, it allows an exact and constant indication of the level of fluid inside the tank.
Supplied with O-ring and allen screw M4 for the fixing.
Especially designed for application on agricultural, earth moving, building machinery and hydraulic units.
Temperature during use 80°C max. Avoid contacts with alcohol and solvents.
On request, provided in different colours.
|
|
 |
|
 |
|
 |
| PLE |
 |
| Vertical level indicator with electrical contact. |
|
Used for the control of the fluid for tanks. The electrical sensor indicates through a visual signal the attainment of the minimal level of the fluid.
The contacts are normally opened, they close to the attainment of the minimal level.
Supplied complete of connector and 2,5 mt cable.
Electrical characteristics:
- Electrical protection: as per norm IP67
- Maximum load on the electrical contacts:
- AC till 250 Volt – 0,5 Ampère
- DC till 250 Volt – 0,5 Ampère
- Concurred liquid specific weight: min. 0,80 kg/dm³
For further information please demand the electrical plan.Avoid contacts with alcohol, trichloroethylene and solvents.
Available with metric thread 12x1,75 and 10x1,5
|
|
|
|
|
|
Visual level indicator with float system.
|
|
Composed of aluminium light alloy female cover with visual dial. It is screwed on burnished steel sleeve which is welded onto the machine cover or tank. Complete with float system, it allows an exact and constant indication of the level of fluid inside the
tank. Especially designed for application on agricultural, earth moving, building machinery and hydraulic
units.Avoid contacts with alcohol and solvents.
Available with gas thread 2” and metric thread 60x2
|
|
|
| GLV |
|
Vertical level indicator with double thread.
|
|
Vertical level indicator with double thread to
control fluid level. Realized with black anodizated aluminium light alloy little
blocks and transparent tube; available completed with O-Rings. Avoid contact
with petrol, benzine, alcohol, petroleum, solvents.
Available with gas thread 3/8".
|
|
 |
|
 |
|
 |
| PLT |
| Vertical level
indicator withthermometer. |
|
Used for checking fluid level in large tanks. Complete with
seals, thermometer, screws and anchor nuts. Easy to assemble, it gives a tolerance of 0,5 mm
along the interhole axis, maintaining a perfect seal. Avoid contact with alcohol
and solvents.
Availabe with tthread M10 and M12.
|
|
|
| PL |
| Vertical level
indicator. |
|
Used for checking fluid level in large tanks. Complete with
seals, screws and anchor nuts. Easy to assemble, it gives a tolerance of 0,5 mm along the interhole
axis, maintaining a perfect seal. Avoid contact with
alcohol and solvents.
Availabe with thread M10 e M12.
|
|
|
| GLVS |
| Vertical level indicator
with single thread. |
|
Vertical level indicator with single thread to control fluid
level. Realized with black anodizated aluminium light alloy little blocks and transparent tube;
available completed with O-Rings. Avoid contact with petrol, benzine, alcohol,
petroleum, solvents.
Available with gas thread 3/8".
|
|